
- Qingqingquan
- Shandong
- 20 days
- 300 units per month
Professional ultrapure water systems for lens cleaning. 18.2 MΩ·cm resistivity, <5 ppb TOC, 0.2μm filtration. Download technical specifications and case studies.
Lens Cleaning Ultrapure Water Systems - 2025 Technical Guide
Why 18.2MΩ·cm Water is Critical for Optical Lens Manufacturing
✔ Eliminates micro-scratches - 0.2μm particle filtration prevents surface damage
✔ Prevents mineral residues - Zero TDS ensures spot-free drying
✔ Maintains coating integrity - Neutral pH protects delicate anti-reflective layers
✔ Reduces rejection rates - 99.8% first-pass yield with proper water quality
Industry Fact: 90% of optical lens manufacturing defects originate from impure cleaning water
3 System Configurations
1. Compact Lab Units (50-200L/h)
For: R&D labs, small production lines
Resistivity: 18.0-18.2 MΩ·cm
Features:
• Benchtop design
• 0.2μm final filtration
• Touchscreen control
2. Production Line Systems (500-2000L/h)
For: Medium-volume manufacturing
Resistivity: 18.1-18.2 MΩ·cm
Features:
• Multi-tank recirculation
• Continuous monitoring
• Automated sanitization
3. Industrial Scale Systems (2-10m³/h)
For: High-volume lens production
Resistivity: 18.2 MΩ·cm
Features:
• Redundant polishing loops
• Cloud-based monitoring
• Validation support
Technical Specifications
Parameter | Specification |
---|---|
Resistivity | 18.2 MΩ·cm @25°C |
TOC | <5 ppb |
Particles | <1/ml (>0.2μm) |
Silica | <2 ppb |
Bacteria | <1 CFU/100ml |
5 Competitive Advantages
✔ Double-pass RO+EDI - Chemical-free operation
✔ NASA-grade filtration - 0.2μm absolute final filters
✔ Real-time monitoring - 24/7 resistivity and TOC tracking
✔ Zero dead-leg design - Prevents bacterial growth
✔ Membrane warranty - Industry's longest coverage
Case Study: Reduced lens rejection rate by 65% at major optical manufacturer
Water Quality Standards for Optics
Critical Parameters
• Resistivity: 18.2 MΩ·cm
• Particles: >0.2μm removal
• Ions: Na⁺ <0.05 ppb, Cl⁻ <0.1 ppb
• Organics: TOC <5 ppb
• Microbes: <1 CFU/100ml
Quality Verification
• Continuous monitoring: Resistivity and TOC
• Daily testing: Particle counts and bacterial endotoxins
• Weekly validation: Ion chromatography analysis
• Monthly certification: Full ASTM D5127 compliance
Maintenance Protocol
✅ Daily: Sensor calibration and integrity tests
✅ Weekly: Filter inspection and replacement
✅ Monthly: Membrane performance validation
✅ Quarterly: System sanitization and recalibration
✅ Annually: Complete system revalidation
Pro Tip: Maintain positive pressure in distribution loops to prevent contamination
Applications in Optical Industry
1. Precision Lens Cleaning
• Camera and microscope lenses
• Eyeglass and contact lens manufacturing
• Telescope and binocular optics
2. Optical Coating Preparation
• Surface pre-treatment
• Post-coating rinsing
• Quality control testing
3. Research & Development
• Laboratory experiments
• Prototype development
• Quality assurance testing
Why Choose Our Systems?
✔ years optical industry experience
✔ ISO 9001/13485 certified manufacturing
✔ 24/7 technical support with rapid response