• Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
Integrated Reverse Osmosis Water Systems - 2025 Technical Guide
  • Qingqingquan
  • Shandong
  • 20 days
  • 300 units per month

Integrated RO water systems producing 0.5-5 m³/h of pure water. Compact design, easy installation, compliant with international standards. Download technical specifications.

Integrated Reverse Osmosis Water Systems - 2025 Technical Guide



Why Choose Integrated RO Systems for Pure Water Production

✔ Space-saving design - 60% smaller footprint than traditional systems

✔ Plug-and-play installation - Reduced from 5 days to 5 hours

✔ Energy efficient operation - 30% lower power consumption

✔ Compliant with international standards - Meets WHO and NSF/ANSI 58 standards


Industry Fact: Integrated RO systems reduce installation costs by 45% compared to modular setups


compact reverse osmosis machine

Technical Specifications


ParameterSpecification
Capacity Range0.5-5 m³/h (Standard: 1 m³/h)
Dimensions2200×680×2600 mm
Output Quality<10 ppm TDS
Power Consumption2.5-4.0 kWh/m³




5 Key Advantages of Integrated Systems

1. Space Optimization

 • Unified enclosure - Houses all components in single cabinet

 • Vertical design - Minimal floor space requirement

 • Mobile configuration - Optional wheels for relocation


2. Simplified Operation

 • Touchscreen control - Intuitive PLC interface with visual indicators

 • Automatic operation - Self-diagnosis and cleaning cycles

 • Remote monitoring - IoT connectivity for performance tracking


3. Enhanced Reliability

 • Pre-engineered components - Perfectly matched system components

 • Reduced connection points - Minimizes leakage risks

 • Factory testing - Pre-commissioned for guaranteed performance


4. Cost Efficiency

 • Lower installation costs - No additional piping or wiring needed

 • Reduced maintenance - Easy access to all components

 • Energy recovery - Optional ERD available for high-efficiency models


5. Water Quality Assurance

 • Multi-stage filtration - 5-step purification process

 • Real-time monitoring - Continuous TDS and quality verification

 • Automatic sanitization - UV and ozone protection systems




Application Scenarios

1. Commercial Enterprises

 • Office buildings and corporate campuses

 • Employee drinking water solutions

 • Kitchen and cafeteria water supply


2. Educational Institutions

 • School and university drinking stations

 • Laboratory water requirements

 • Campus-wide water distribution


3. Healthcare Facilities

 • Hospital drinking water systems

 • Dental clinic water requirements

 • Medical equipment water supply


4. Hospitality Industry

 • Hotel and restaurant drinking water

 • Kitchen cooking water preparation

 • Bar and beverage preparation


5. Residential Communities

 • Apartment building water stations

 • Housing complex drinking water

 • Community water distribution points



integrated RO water system

System Components

1. Pretreatment System

 • Multi-media filtration - Removes sediments and particles

 • Activated carbon filtration - Eliminates chlorine and organics

 • Water softening - Prevents scale formation

 • Precision filtration - 5μm final pre-filter


2. RO Membrane System

 • Dow Filmtec membranes - 99% salt rejection rate

 • Stainless steel housing - Corrosion-resistant construction

 • Automatic flushing - Membrane protection system


3. Post-Treatment

 • Remineralization - Taste enhancement

 • UV sterilization - 99.99% microorganism removal

 • Final filtration - 0.2μm absolute filtration


4. Control System

 • PLC controller - Automated operation

 • Touchscreen interface - Easy parameter setting

 • Safety protections - Multiple failure prevention systems




Performance Data


ContaminantFeed WaterProduct WaterRemoval Rate
TDS500 ppm<10 ppm98%
Chlorine2.0 ppm0 ppm100%
Bacteria100 CFU/ml0 CFU/ml100%
Heavy Metals0.5 ppm<0.01 ppm98%




Maintenance Features

✅ Automatic flushing - Extended membrane life

✅ Filter change indicators - Timely maintenance reminders

✅ Self-diagnosis system - Early fault detection

✅ Easy access design - Quick maintenance and part replacement

✅ Remote monitoring - Performance tracking and alerts


Pro Tip: Regular membrane cleaning every 3-6 months maintains optimal system performance



Why Choose Our Integrated Systems?

✔ 10 years integration experience - Proven reliability

✔ Global certifications - CE, ISO, NSF standards

✔ 24/7 technical support - Expert assistance available

✔ Custom solutions - Tailored to specific requirements



RO water system manufacturercommercial reverse osmosis supplierReverse Osmosis System Water Treatment Equipment Application


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right