IV. Industrial RO system operation and maintenance management and fault prevention

4.1 Daily maintenance points

 Pressure monitoring: Regularly check the inlet water pressure, the pressure difference between the segments, the pressure difference rises 15% need to be cleaned immediately.

 Flow balance: Ensure that the ratio of concentrated water flow to produced water flow meets the design value to avoid concentration polarization on the membrane surface.

 Chemical cleaning: Select cleaning agent according to the type of membrane contamination (such as citric acid descaling, NaOH in addition to organic matter), cleaning every 3-6 months.


4.2 Common Failures and Solutions


4.3 Five Strategies to Extend Membrane Life

 Strict Pre-treatment: Ensure that the feed water SDI is <3, and reduce the deposition of contaminants on the membrane surface.

 Standardized operation: Avoid frequent start/stop of the system or sudden pressure changes to prevent mechanical damage to the membrane.

 Regular Maintenance: Perform chemical cleaning and performance testing as scheduled to restore membrane flux.

 Shutdown protection: For long term shutdowns, membrane elements need to be immersed in a protective solution (e.g. 1% sodium bisulfite solution).

 Data-driven: the establishment of operating logs, through trend analysis, early warning of membrane performance degradation.


Reverse Osmosis System Water Treatment Equipment Application

V. Application cases of industrial RO system

5.1 Electronics industry: ultrapure water preparation

 A semiconductor enterprise adopts the “two-stage RO + EDI + polishing resin” process, the resistivity of the produced water reaches 18.2MΩ-cm, which meets the requirements of the chip cleaning water, and the recovery rate of the system is increased to 85%, with an annual saving of more than 2 million yuan in water costs.


5.2 Pharmaceutical industry: preparation of water for injection

 A pharmaceutical company through the “RO + multi-effect distillation” combined process, the produced water meets the Chinese Pharmacopoeia standard for water for injection, bacterial endotoxin <0.015EU/mL, the stability of the system operation of more than 99.9%.


5.3 Power industry: boiler make-up water

 A thermal power plant adopts “ultrafiltration + RO + mixed bed” process, the hardness of produced water is <0.02μmol/L, which effectively prevents boiler scaling and extends the service life of the equipment for 3-5 years.


Reverse Osmosis System Water Treatment Equipment


Conclusion

 Industrial RO system as the core equipment for process water treatment, its performance is directly related to product quality and production costs. Enterprises need to control the whole chain from system design, component selection, process optimization to operation and maintenance management, and customized solutions combined with industry characteristics, in order to achieve efficient use of water resources and maximize economic benefits.


 With the continuous breakthrough of membrane material technology and intelligent control, industrial RO system is developing towards higher desalination rate, lower energy consumption and longer life, providing key technical support for industrial green transformation.


Industrail RO System Water Treatment Machine Manufacturer

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy